We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

Chronically implantable, closed-loop neuromodulation devices with concurrent sensing and stimulation hold promise for better understanding the nervous system and improving therapies for neurological disease. Concurrent sensing and stimulation are needed to maximize usable neural data, minimize time delays for closed-loop actuation, and investigate the instantaneous response to stimulation. Current systems lack concurrent sensing and stimulation primarily because of stimulation interference to neural signals of interest. While careful design of high performance amplifiers has proved useful to reduce disturbances in the system, stimulation continues to contaminate neural sensing due to biological effects like tissue-electrode impedance mismatch and constraints on stimulation parameters needed to deliver therapy. In this work we describe systematic methods to mitigate the effect of stimulation through a combination of sensing hardware, stimulation parameter selection, and classification algorithms that counter residual stimulation disturbances. To validate these methods we implemented and tested a completely implantable system for over one year in a large animal model of epilepsy. The system proved capable of measuring and detecting seizure activity in the hippocampus both during and after stimulation. Furthermore, we demonstrate an embedded algorithm that actuates neural modulation in response to seizure detection during stimulation, validating the capability to detect bioelectrical markers in the presence of therapy and titrate it appropriately. The capability to detect neural states in the presence of stimulation and optimally titrate therapy is a key innovation required for generalizing closed-loop neural systems for multiple disease states.

Original publication

DOI

10.1109/tnsre.2012.2183617

Type

Journal article

Journal

IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society

Publication Date

07/2012

Volume

20

Pages

410 - 421

Addresses

Medtronic Neuromodulation, Minneapolis, MN 55432, USA. scott.stanslaski@medtronic.com

Keywords

Brain, Animals, Sheep, Electroencephalography, Monitoring, Ambulatory, Deep Brain Stimulation, Equipment Design, Equipment Failure Analysis, Prostheses and Implants, Action Potentials, Feedback, Signal Processing, Computer-Assisted, Biofeedback, Psychology