Research groups
OxCIN MRS Group
-
Chiara Coletti
Marie Skłodowska-Curie Postdoctoral Fellow
-
Vasilis Karlaftis
Research Software Engineer
-
Jason Lyu
DPhil Student
William Clarke
Associate Professor & Wellcome Career Development Fellow
Advanced, open tools for MR Spectroscopy
My work focusses on developing new methods for magnetic resonance spectroscopy (MRS). Using similar methods to MR imaging (MRI), MRS allows us to quantify the concentrations and chemical kinetics of many neurochemicals in the human brain. Furthermore, by using neurochemicals as endogenous probes we can also map cell-type-specific microstructure. My work seeks to develop new ways of acquiring multi-voxel spectroscopic information to measure chemical dynamics and cellular microstructure across the brain. I have released the open-science MRS analysis tool FSL-MRS and created a range of open-source tools for the MRS community. I am a cofounder of the educational website MRSHub.
In 2023 I started a spectroscopy group at WIN funded by a Wellcome Career Development Award. Previously I have worked as spectroscopist in the Physiological Neuroimaging Group and as a post-doctoral researcher in the UK7T Network. Prior to working in neuroimaging, I completed my doctorate in cardiovascular magnetic resonance spectroscopy. This work focused on the high-energy phosphorus metabolism of the human myocardium.
I am open to consulting on acquisition and analysis of MR spectroscopy for clinical trials, and have previously done so for third-party CROs.
I accept applications for DPhil (phd) students to my group. Please see below for more information.
DPhil Project Opportunities
1. Development of Diffusion MRSI Using Pulseq
Diffusion-weighted magnetic resonance spectroscopy (DW-MRS) provides a unique window into tissue microstructure by measuring the diffusion of intracellular metabolites, rather than water. Extending these measurements to magnetic resonance spectroscopic imaging (MRSI) would enable spatially resolved investigations of metabolite diffusion across the brain, potentially providing new insights into cellular structure, compartmentation and changes associated with neurological disease. However, diffusion MRSI remains technically challenging, with demanding requirements for sequence design, signal stability, spatial encoding and acquisition efficiency.
This project will develop a diffusion-weighted MRSI sequence using Pulseq, an open-source framework for vendor-independent MRI pulse sequence development. The student will investigate suitable diffusion preparation and spectroscopic imaging strategies, implement and optimise the sequence, and evaluate its performance using simulations, phantoms and in vivo measurements. A key aim will be to establish a flexible, reproducible implementation that can be shared across MRI platforms, facilitating wider adoption and further development of diffusion MRSI.
2. Motion and B0 Field Tracking for MRSI
Magnetic resonance spectroscopic imaging (MRSI) is particularly sensitive to subject motion and changes in the main magnetic field (B0), which can cause spectral distortions, signal loss and spatial inconsistencies during relatively long acquisitions. These problems are especially pronounced at ultra-high magnetic fields such as 7T, limiting the robustness and reproducibility of MRSI in both research and clinical applications. Real-time measurement and correction of motion and field fluctuations offers a promising route to improving data quality and making advanced spectroscopic imaging more reliable.
This project will investigate methods for tracking and correcting motion and B0 changes during MRSI acquisitions, potentially using wireless RF-activated field probes (WRAD). The student will develop approaches to integrate external tracking information into MRSI acquisition and reconstruction, exploring prospective correction of imaging geometry, frequency offsets and other relevant acquisition parameters, alongside retrospective correction strategies where appropriate. The project will combine MR sequence development, hardware integration, signal processing and experimental validation, with the aim of improving the robustness of high-resolution MRSI at 7T.
3. Fully Parallel Transmit-Enabled MRSI at 7T
Ultra-high-field MRI at 7T offers substantial benefits for proton magnetic resonance spectroscopic imaging (¹H-MRSI), including increased signal-to-noise ratio and improved spectral resolution. However, spatial variations in the transmit radiofrequency field (B1+) present major challenges for achieving uniform excitation, effective water suppression and reliable spectral localisation across the brain. Parallel transmission (pTx), using multiple independently controlled transmit channels, provides opportunities to address these limitations through tailored radiofrequency pulse design, but its full potential has yet to be realised in MRSI.
This project aims to develop a fully pTx-enabled implementation of proton MRSI at 7T, extending parallel transmission beyond excitation to encompass water suppression, refocusing where required, and other RF components of the spectroscopic imaging sequence. The student will investigate RF pulse design, B1+ and B0 field modelling, sequence integration and optimisation under relevant hardware and safety constraints. Through simulations, phantom experiments and in vivo validation, the project will explore whether comprehensive pTx optimisation can improve spectral quality, spatial coverage and reproducibility, enabling more reliable whole-brain or large-volume metabolite mapping at ultra-high field.
Funding and applications
Please note that these projects do not come with dedicated studentship funding. Interested candidates will need to apply for admission to the University of Oxford's DPhil in Clinical Neurosciences and secure funding through the University's competitive scholarship schemes or other sources, unless they have already arranged suitable funding independently.
Prospective applicants are encouraged to contact Associate Professor William Clarke in plenty of time to discuss their interests, background and potential project before submitting a formal application. Candidates with backgrounds in physics, engineering, mathematics, computer science or related disciplines, and an interest in MRI methods development, are particularly encouraged to enquire. Prior experience in MRS or MRI is not required.
Introduction to Magnetic Resonance Spectroscopy Acquisition and Analysis
Open-source MRS Software
FSL-MRS - End to end MRS analysis software
FSLeyes (+ plugin): MRS and MRSI visualisation
Spec2nii: Multi-format in vivo MR spectroscopy conversion to NIFTI
- NIfTI-MRS software tools and standard
Key publications
NIfTI-MRS: A standard data format for magnetic resonance spectroscopy
Journal article
CLARKE W. et al, (2022), Magnetic Resonance in Medicine
FSL‐MRS: An end‐to‐end spectroscopy analysis package
Journal article
Clarke WT. et al, (2021), Magnetic Resonance in Medicine, 85, 2950 - 2964
Multi-site harmonization of 7 tesla MRI neuroimaging protocols
Journal article
Clarke WT. et al, (2020), NeuroImage, 206, 116335 - 116335
Creatine kinase rate constant in the human heart measured with 3D‐localization at 7 tesla
Journal article
Clarke WT. et al, (2017), Magnetic Resonance in Medicine, 78, 20 - 32
Recent publications
A Framework for SPICE MRSI Reconstruction Posterior Uncertainty Quantification
Preprint
Lyu T. et al, (2026)
The Impact of BOLD‐Induced Linewidth Modulation on Functional 1 H MRS Analysis
Journal article
Wilson M. et al, (2026), NMR in Biomedicine, 39
Longitudinal neurochemical profiling after experimental stroke using edited MR spectroscopy
Preprint
Grigoras IF. et al, (2026)
Breathlessness catastrophising after COVID-19 involves both interoceptive and visceromotor connectivity
Preprint
Qiu L. et al, (2026)
Fully automated open-source analysis and interactive visualization of magnetic resonance spectroscopic imaging (MRSI) data in Osprey-MRSI
Preprint
Zöllner HJ. et al, (2026)