We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

OBJECTIVES: To review the optimal diagnostic cut-off of ultrasonographic optic nerve sheath diameter (ONSD) in the diagnosis of increased intracranial pressure (IICP). METHODS: A systematic search was conducted of available studies assessing the use of ONSD ultrasonography in patients with suspected IICP. Meta-analysis of diagnostic accuracy of ultrasonographic ONSD was performed using a bivariate model of random effects to summarize pooled sensitivity and specificity. A summary receiver operating characteristics (SROC) curve was plotted. Accuracy measures associated with ONSD cut-off and predefined covariates were investigated with meta-regression. RESULTS: We included 38 studies, comprising a total of 2824 patients. A total of 21 studies used invasive techniques as a reference standard estimation of IICP and meta-analysis revealed a pooled sensitivity of 0.90 (95% CI 0.85-0.93) and specificity of 0.87 (95% CI 0.80-0.91). Optimal ONSD cut-off values ranged between 4.1 mm and 7.2 mm. Meta-regression analysis showed that ONSD cut-off values of 5.6 to 6.3 mm were associated with higher pooled specificity compared to cut-off values of 4.9 to 5.5 mm (0.93, 95% CI 0.85-0.97 vs. 0.78, 95% CI 0.65-0.87; p = 0.036). CONCLUSIONS: Ultrasonography of ONSD shows a high diagnostic accuracy for IICP, with high pooled sensitivity and specificity. Additionally, larger cut-off values seem to significantly increase specificity without compromising sensitivity, which support their use as optimal ONSD cut-off. The overall high sensitivity of ultrasonographic ONSD suggests its usefulness as a screening tool for IIC, which may provide an estimate of when invasive methods are warranted. CLINICAL RELEVANCE: ONSD ultrasonography is a fast and cost-effective method with a high diagnostic accuracy to detect IICP. The optimum ONSD cut-off hasn't been established before, but we suggest the 5.6 to 6.3 mm range as the best for the diagnosis of IICP.

Original publication

DOI

10.1016/j.jns.2023.120853

Type

Journal article

Journal

J Neurol Sci

Publication Date

15/11/2023

Volume

454

Keywords

Intracranial pressure, Optic nerve sheath, Optic nerve sheath diameter, Ultrasonography, Humans, Intracranial Pressure, Optic Nerve, Intracranial Hypertension, Sensitivity and Specificity, Ultrasonography